Waterproofing for roofs, terraces, bathrooms and foundations

Choose waterproofing for roofs, terraces, bathrooms, swimming pools and foundations. The catalogue includes liquid membranes, cementitious and bituminous coatings, sheet membranes and system components from Sika, MC-Bauchemie, Sherwin-Williams and Topciment. Browse the applications below or use the brand and product-type filters to compare solutions for your project.

Sort by:

Nafuflex Easy Tech 1 – пръскаема битумна хидроизолация / 30 l

Цена по запитване
Nafuflex Easy Tech 1 е бързосъхнещо, еднокомпонентно и пръскаемо полимерно-модифицирано битумно дебело покритие (PMBC) за хидроизолация на сгради.Области на приложение Хидроизолация на вертикални, хоризонтални и наклонени повърхности под защитни слоеве...
MC-Injekt 2300 flow – комплект 20 l

MC-Injekt 2300 flow – еластична инжекционна смола / комплект 20 l

Цена по запитване
MC-Injekt 2300 flow е дуктилно-еластична, трайно уплътняваща и реагираща с влагата полиуретанова инжекционна смола за бетон, зидария и строителни основи.Области на приложение Еластично запълване и уплътняване на пукнатини, строителни фуги...

MC-Injekt PowerSeal R – водоспираща експандираща инжекционна смола / 10 l

Цена по запитване
MC-Injekt PowerSeal R е еднокомпонентна, водоспираща и еластично уплътняваща експандираща смола за строителни основи, бетон и зидария.Области на приложение Еластично уплътняване на пукнатини, фуги и кухини във влажни бетонни и...
Nafuflex Basic 1 – опаковка 30 l

Nafuflex Basic 1 – бързосъхнеща битумна хидроизолация / 30 l

Цена по запитване
Nafuflex Basic 1 е еднокомпонентно, много бързосъхнещо полимерно-модифицирано битумно дебело покритие (PMBC) за хидроизолация на строителни конструкции.Области на приложение Хидроизолация на вертикални, хоризонтални и наклонени повърхности под защитни слоеве съгласно...
SIKA IGOLFLEX-201 DE, дву компонентна полимер-битумна хидроизолация / 28 кг

SIKA IGOLFLEX-201 DE, 2-component polymer-bitumen waterproofing / 28 kg

Цена по запитване
SIKA IGOLFLEX-201 DE, дву компонентна полимер-битумна хидроизолация от Sika. Цена с ДДС, категория Течни хидроизолационни мембрани. Разфасовки: 28 кг. Чернова за проверка преди публикуване.
SikaShield P45 MG 4,5 kg/m2 - APP -10 /+130 oC, армировка полиестер, сива посипка / 10 м²

SikaShield P45 MG 4.5 kg/m² - APP -10 / +130 °C, polyester reinforcement, grey slate finish / 10 m²

Цена по запитване
SikaShield P45 MG 4,5 kg/m2 - APP -10 /+130 oC, армировка полиестер, сива посипка от Sika. Цена с ДДС, категория Битумни рулонни хидроизолационни мембрани. Разфасовки: 10 м². Чернова за проверка преди публикуване.
SikaShield P45 PE 4 kg/m2 - APP -10 /+130 oC, армировка полиестер / 10 м²

SikaShield P45 PE 4 kg/m² - APP -10 / +130 °C, polyester reinforcement / 10 m²

Цена по запитване
SikaShield P45 PE 4 kg/m2 - APP -10 /+130 oC, армировка полиестер от Sika. Цена с ДДС, категория Битумни рулонни хидроизолационни мембрани. Разфасовки: 10 м². Чернова за проверка преди публикуване.
Sika Monoseal-101 сив , еднокомпонентна хидроизолация / 20 кг

Sika Monoseal-101 grey, 1-component waterproofing / 20 kg

Цена по запитване
Sika Monoseal-101 сив , еднокомпонентна хидроизолация от Sika. Цена с ДДС, категория Цименто-полимерни и акрилатни хидроизолации, ленти. Разфасовки: 20 кг. Чернова за проверка преди публикуване.
Sikalastic 6100 FX UV устойчива циментова хидроизолация 15 kg

Sikalastic®-6100 FX - UV-Resistant Elastic Cementitious Waterproofing 15 kg

Цена по запитване
Sikalastic®-6100 FX е еднокомпонентна еластична циментова мембрана за хидроизолация и защита на бетон. UV устойчива, подходяща за вътрешно и външно приложение, под плочки, фундаменти, басейни, малки покриви и балкони.
SikaSwell® S-2 - набъбващ полиуретанов уплътнител за фуги

SikaSwell® S-2 - Swellable Polyurethane Joint Sealant

Цена по запитване
SikaSwell® S-2 е 1-компонентен хидрофилен набъбващ полиуретанов уплътнител за конструктивни фуги и прониквания в бетон. Използва се и за фиксиране на SikaSwell® A/P профили и SikaFuko® Swell 1 маркучи.
SikaSwell® A - Акрилни набъбващи профили за уплътняване на фуги

SikaSwell® A - Acrylic Swelling Profile for Joints in Concrete

Цена по запитване
SikaSwell® A са акрилни набъбващи профили за конструктивни фуги, тръбни преминавания, метални елементи, кабелни канали и други прониквания в бетон. Набъбват при контакт с вода и подпомагат уплътняването.
SikaSwell® P Type H - водонабъбващ профил за конструктивни фуги

SikaSwell® P Type H - water-swellable profile for construction joints

Цена по запитване
SikaSwell® P Type H е хидрофилен набъбващ профил с каучукова EPDM сърцевина за конструктивни фуги и прониквания в бетон. При контакт с вода набъбва и уплътнява фуги, отвори за тръби и кабелни канали.
Sika Waterbar® DF AT - външен водоспиращ профил за дилатационни фуги

Sika Waterbar® DF AT - External Waterstop Profile for Expansion Joints

Цена по запитване
Sika Waterbar® DF AT са повърхностно разположени PVC-P водоспиращи профили за дилатационни фуги. Монтират се от външната страна на бетона и са подходящи за фуги с движение във водонепропускливи конструкции.
Sika Waterbar® D AT - централен водоспиращ профил за дилатационни фуги

Sika Waterbar® D AT - Central Waterstop Profile for Expansion Joints

Цена по запитване
Sika Waterbar® D AT са централно разположени PVC-P водоспиращи профили за дилатационни фуги в нови бетонни конструкции. Подходящи са за фуги, които трябва да поемат движение и да останат водонепропускливи.
Sika Waterbar® FB Bracket - фиксираща скоба за Sika Waterbar FB-125

Sika Waterbar® FB Bracket - Fixing Bracket for Sika Waterbar® FB-125

Цена по запитване
Sika Waterbar® FB Bracket е фиксираща скоба за Sika Waterbar® FB-125. Използва се за стабилно позициониране на профила в пресния бетон и за намаляване на риска от изместване преди и по време на бетониране.
Sika Waterbar FB-125 - Гъвкав водоспиращ профил за уплътняване на конструктивни фуги който залепва към бетона

Sika Waterbar® FB-125 – Bonded Waterbar Profile for Construction Joints

Цена по запитване
Sika Waterbar® FB-125 е гъвкав FPO водоспиращ профил с текстурирана повърхност, който залепва към бетона. Поставя се в пресния бетон и осигурява напълно залепено уплътняване на конструктивни фуги.
Sika Waterbar® AF AT - външен водоспиращ профил за конструктивни фуги

Sika Waterbar® AF AT - External Waterstop Profile for Construction Joints

Цена по запитване
Sika Waterbar® AF AT са повърхностно разположени PVC-P водоспиращи профили за конструктивни фуги. Монтират се от външната страна на бетона и са подходящи за фундаменти, подземни гаражи и водозадържащи структури.
Sika Waterbar® A AT - централен водоспиращ профил за конструктивни фуги

Sika Waterbar® A AT - Central Waterstop Profile for Construction Joints

Цена по запитване
Sika Waterbar® A AT са централно разположени PVC-P водоспиращи профили за конструктивни фуги в нови бетонни конструкции. Подходящи са за фундаменти, подземни паркинги, гаражи и водозадържащи структури.
Sikadur-Combiflex® CF Adhesive Normal - епоксидно лепило за Combiflex SG

Sikadur-Combiflex® CF Adhesive Normal - epoxy adhesive for Combiflex SG

Цена по запитване
Sikadur-Combiflex® CF Adhesive Normal е 2-компонентно тиксотропно епоксидно лепило за залепване на FPO ленти Sikadur-Combiflex® SG към бетон, зидария, разтвор, камък и стомана при вътрешни и външни приложения.
Sikadur-Combiflex® SG-10 M - хидроизолационна лента 1.0 mm за фуги

Sikadur-Combiflex® SG-10 M - 1.0 mm Waterproofing Tape for Joints

Цена по запитване
Sikadur-Combiflex® SG-10 M е FPO хидроизолационна лента 1.0 mm за разширителни фуги, работни фуги, пукнатини и конструктивни детайли. Лентата е част от системата Sikadur-Combiflex® SG и се залепва със системно епоксидно лепило.
Sikadur-Combiflex® SG-20 M300 - хидроизолационна лента 2.0 mm за фуги

Sikadur-Combiflex® SG-20 M300 – 2.0 mm Waterproofing Tape for Joints

Цена по запитване
Sikadur-Combiflex® SG-20 M300 е FPO хидроизолационна лента 2.0 mm за дилатационни фуги, работни фуги, пукнатини и конструктивни детайли. Част е от системата Sikadur-Combiflex® SG и се монтира със съвместимо епоксидно лепило.
Sika® SealTape F - хидроизолационна лента за пукнатини и басейни

Sika® SealTape F - waterproofing tape for cracks and swimming pools

Цена по запитване
Sika® SealTape F е еластична хидроизолационна лента за премостване на пукнатини и детайли в мокри помещения, басейни, тераси, автомивки и професионални кухни.
Sika® SealTape S - хидроизолационна лента за баня под плочки

Sika® SealTape S – waterproofing tape for bathrooms under tiles

Цена по запитване
Sika® SealTape S е еластична хидроизолационна лента за ъгли, фуги и тръби под плочки в бани, мокри помещения, балкони и тераси. Не е за басейни.
Sikalastic®-200 W - течна хидроизолация под плочки

Sikalastic®-200 W - liquid waterproofing under tiles

Цена по запитване
Sikalastic®-200 W е готова 1-компонентна еластична течна хидроизолация за вътрешни влажни помещения под керамични плочки или камък.

How to choose the right waterproofing system

Waterproofing combines materials and details to prevent water entering a structure. Selection starts with the application, the substrate and the way water acts on it. A roof exposed to sunlight and rain, a bathroom beneath tiles and a basement wall in contact with the ground each place different demands on the coating.

Before comparing products, establish whether you are installing a new system, repairing existing waterproofing or addressing a local leak. Then identify what will cover the waterproofing: an exposed surface, ceramic tiles, a protective layer, soil or asphalt. This helps you select a material for the actual application rather than relying on a general “water-resistant” description.

The water resistance of an individual material does not establish that the complete structure is watertight. The main waterproofing layer must connect properly to joints, corners, drains and pipe penetrations. This category therefore includes waterproofing materials alongside primers, tapes, reinforcement and other system components.

Types of waterproofing in the catalogue

Liquid membranes and polymer coatings

Liquid membranes are applied to a prepared substrate to form a continuous coating. They can accommodate complex shapes, upstands and penetrations, provided the details follow the selected system. Different polymer formulations have different requirements for primers, residual moisture, reinforcement and protective finishes.

For an exposed roof, check resistance to weathering and UV exposure. For a terrace subject to regular foot traffic, also establish the permitted mechanical loading. Flexibility, UV resistance and resistance to pedestrian traffic are separate properties.

Cementitious and polymer-modified waterproofing

Cementitious waterproofing is used on suitable mineral substrates. The group includes one-component and two-component products with different levels of flexibility and intended uses. Suitability beneath tiles, inside a tank or under negative water pressure must be established for the specific material. The properties of one product cannot be applied to all cementitious formulations.

Bituminous waterproofing coatings

Bituminous coatings are among the options for external protection of building elements in contact with the ground. Selection depends on water exposure, the required thickness, substrate preparation and protection before backfilling. For example, Nafuflex Basic 1 from MC-Bauchemie is a thick-layer bituminous coating for use beneath protective layers. This does not make it an exposed finish for every surface.

Sheet membranes, tapes and sealing details

With sheet waterproofing, the fixing or bonding method, sheet connections, overlaps and edge details are critical. Waterproofing tapes, collars and other sealing components serve specific functions within the system. They protect individual connections and do not replace the main membrane across the full area.

Choosing waterproofing for the application

Roof waterproofing

For roof waterproofing, first establish the substrate type and condition. On refurbishment projects, assess adhesion of the existing coating, blisters, moisture within the build-up and compatibility with the new material. Applying another layer does not make a poorly bonded or unstable existing system sound.

Check falls, drainage, connections to upstands and areas around service penetrations. Standing water is a specific exposure condition to consider when choosing a product; suitability must not be assumed for every roof membrane. If the coating will remain exposed, the system must be intended for that use.

Waterproofing for terraces and balconies

For terraces and balconies, distinguish an exposed coating from waterproofing beneath tiles. In a tiled system, compatibility with the adhesive, covering and edge details needs to be checked. MC-Proof DF 10 is an example in the catalogue with applications beneath ceramic coverings, including balconies and terraces.

Threshold connections, drains and movement joints form part of the solution. A thicker waterproofing layer cannot compensate for incorrect falls, loose tiles or an unstable screed. Where a covering already exists, assess whether it can remain as the substrate for the selected system.

Waterproofing for bathrooms and wet rooms

For bathroom waterproofing, tiles and water-resistant grout do not replace a continuous waterproof layer. Floor-to-wall junctions, shower areas, drains and pipe penetrations need particular attention. Suitable tapes and collars must work with the main coating.

Identify the substrate itself: concrete, screed, render or building board. A material suitable for one must not automatically be assumed suitable for the others. Preparation, the required primer and the waiting time before tiling all matter.

Swimming pool waterproofing

Swimming pool waterproofing must suit continuous water exposure and the specified finish. Suitability for a bathroom does not establish suitability for a swimming pool. SikaTop Seal-107 Elastik has an application in swimming pools before ceramic tiling; this does not make it a universal exposed finish.

Details around inlets, lighting, drains and joints must be planned together with the main area. Establish separate waiting times for tiling and filling the pool. Where a drinking-water tank is involved, that use must be checked explicitly for the chosen material.

Foundations, basements and below-ground structures

For waterproofing foundations and structures, distinguish ground moisture from water under pressure. Positive water pressure acts on the coated side and presses the coating towards the substrate. Negative pressure reaches the coating through the structure and challenges its bond. A material for external application is not automatically suitable for waterproofing a basement from inside.

An external system needs protection against damage during subsequent construction work. An internal solution may restrict water entering the room without stopping the wall from becoming wet on the ground-facing side. The water source, active leaks and connections between structural elements require separate assessment.

Bridges and viaducts

A bridge waterproofing system is a specialist solution. For a concrete bridge deck beneath asphalt, the exact build-up, concrete preparation, bonding between layers and readiness for the next operation are all important. See the dedicated category for the build-up using MBC-VT 116 and Elastomastic TFN. A roof membrane or a system for a steel substrate must not be treated as a direct substitute.

What the complete system should include

The primer, main waterproofing layer, reinforcement and protective finish serve different purposes. The primer prepares the bond to the substrate as required by the system. Reinforcement fabric supports the coating in specified areas but is not a waterproofing membrane on its own. A sealing varnish or a product that improves the water resistance of a decorative finish does not automatically replace a waterproofing layer.

For joint waterproofing, assess movement, width, water exposure and working access. A construction joint, a movement joint and a crack do not call for the same treatment. Simply passing a roller over the area does not create the required sealing detail.

Check what the pack contains before ordering. Component A or B sold separately is not a complete two-component product. Compatibility between the primer, membrane, tape and subsequent coating must be confirmed for the exact combination. This also applies to products from the same brand.

Substrate preparation and application conditions

The substrate must support the required bond: it needs adequate strength and must be cleaned and prepared for the chosen material. Dust, oil, weak layers, cement laitance and incompatible residues can compromise the coating. Plan repairs, levelling and detail work before applying the main waterproofing.

Permitted substrate moisture depends on the product. Some cementitious materials require pre-wetting of the mineral substrate, while other coatings have limits on residual moisture. Suitability for a damp substrate does not mean permission to apply over puddles or running water. Air and substrate temperatures, expected rain and the risk of condensation also affect planning.

Follow the specified thickness and consumption for the complete required build-up. One thick coat does not automatically replace several application layers. For two-component materials, the mixing ratio and procedure are technical requirements; they should not be adjusted by judging consistency alone.

When can the next stage of work begin?

Working time, the interval before another coat and full curing are different measures. A surface that feels dry may not yet be ready for tiling, foot traffic or permanent contact with water.

Plan separately when the next material can be applied, protection installed and the area put into use. Temperature, humidity and layer thickness affect these intervals. Before filling a swimming pool, check the readiness of the complete build-up. For foundations, establish the required curing and protection before backfilling.

Is the problem a leak, condensation or capillary moisture?

A leak allows water to enter through a defect or connection. Condensation occurs when water vapour turns into liquid on a cold surface or within the construction build-up. Capillary moisture and residual construction moisture also require their own assessment. A new waterproof coating is not a universal answer to all these conditions.

Establish when the moisture appears: after rain, when the bathroom is used, continuously in a below-ground wall or mainly during cold weather. A vapour control layer restricts water vapour movement; its need and position depend on the complete construction build-up. It serves a different function from protection against liquid water ingress.

How to compare waterproofing costs per m²

For liquid and coating-applied materials, first calculate the cost of the required quantity of the main material:

Material cost per m² = pack or kit price ÷ quantity in kg or litres × total consumption for the required coats.

Use matching units and the correct consumption basis: dry material or mixed product. For a two-component product, include both components in the required ratio. For sheet membranes, calculate the usable coverage after overlaps. Measure tapes and joints in linear metres.

The complete budget also includes substrate preparation and repairs, primer, reinforcement, sealing details, protective layers and application wastage. Account for available pack sizes when calculating how much to order. Consumption on a rough or highly absorbent substrate may differ from that on a suitable, even surface.

When comparing quotations, separate materials from labour and check that VAT and delivery are included on the same basis. This gives a comparison of solutions for the same task. The lowest pack price alone does not establish the final waterproofing cost for your project.

Information to prepare for product selection and an enquiry

Useful details include the area in m², the length of joints and upstands, substrate type, and photographs showing both the overall area and the problem locations. State whether an existing coating is present, when the leak occurs, the proposed covering or protective layer, and whether the work is indoors or outdoors.

Use the brand and product-type filters to browse the catalogue, then compare intended uses and the complete required build-up. When sending an enquiry from a product page, include these project details and the quantity required. They help identify the main material as well as components that are easily missed in the initial estimate.

Frequently asked questions about waterproofing

Practical answers on selection, preparation, compatibility and system costs.
Can liquid waterproofing remain exposed without tiles?

Liquid waterproofing can remain exposed when the product is intended for that application. Check UV resistance, any required protective layer and the permitted loading. Suitability for an exposed roof does not automatically mean suitability for regular foot traffic.

Can waterproofing be applied over existing tiles?

Application over existing tiles is possible with a system that permits this substrate, after assessing adhesion, moisture and the required preparation. A new coating alone cannot correct loose tiles, an unstable substrate or drainage problems.

Can a waterproofing coating be applied to damp concrete?

Permitted moisture depends on the specific product. Some cementitious materials require pre-wetting, while other coatings have limits on residual moisture. Suitability for a damp substrate does not permit application over puddles or running water.

Can a leaking basement be waterproofed from inside?

Internal waterproofing is possible with a solution intended for negative water pressure and the relevant substrate. It may stop water entering the room without preventing the structure from becoming wet on the ground-facing side. Joints and active leaks require separate assessment.

Are tiles and water-resistant grout enough in a bathroom?

Tiles and grout do not replace continuous waterproofing in wet areas. The main coating must connect correctly to drains, pipes, corners and floor-to-wall junctions.

Can I combine a Sika primer with an MC-Bauchemie membrane?

Products from different brands can be combined where compatibility has been confirmed for the exact materials and layers. A general waterproofing description is insufficient. Even products from the same brand are not necessarily part of one system.

How long should I wait before tiling or filling a swimming pool?

Waiting times for another coat, tiling and water exposure are different. They depend on the specific materials and site conditions. A surface that feels dry is not necessarily ready for tiling or filling the pool.

Why does the pack price not show the waterproofing cost per m²?

Coverage depends on consumption, the required thickness and the number of coats. Preparation, primer, reinforcement, tapes and protection add to the main material cost. For two-component products, include both components in the required ratio.